I have received a Measure-mind 3D program from our sister plant. When I try to run the program,
several steps are incorrectly illuminated. How do I adjust the lighting in my program to the correct values?
1) Open your program in Measure-mind 3D.
2) Select "Edit->Change". Type the step number you wish to change.
3) This will display the step on the right side of the dialog box. Select the "Points" button to reset the meaured points to zero.
4) Now refocus the feature and relearn the points for the feature. Press the "Done" button to save this feature .
5) Save your program.
How do I export measured data to Excel?
To Export your measured data to Excel perform the following steps:
1.Setup the export options to use by selecting "System" -> "Configuration" -> "Output" from the pull down menu. ...