Proper circle measurement techniques in cmm programming
Learn proper measurement techniques using PC DMIS in CMM programming – an argument for measuring diameters with greater than 90 degrees of arc.
http://www.cmmxyz.com/website/Training/Training-home.html
Ayr Location
2492 Cedar Creek Road, #4
Ayr, Ontario N0B 1E0
Phone: (905) 819-7878
1- 800-606-9266
Tech Tips
I have received a Measure-mind 3D program from our sister plant. When I try to run the program,
several steps are incorrectly illuminated. How do I adjust the lighting in my program to the correct values?
1) Open your program in Measure-mind 3D.
2) Select "Edit->Change". Type the step number you wish to change.
3) This will display the step on the right side of the dialog box. Select the "Points" button to reset the meaured points to zero.
4) Now refocus the feature and relearn the points for the feature. Press the "Done" button to save this feature .